Danfoss http://saravanaelectronics.in Mon, 18 Jun 2018 05:14:33 +0000 en-US hourly 1 https://wordpress.org/?v=4.9.4 http://saravanaelectronics.in/wp-content/uploads/2017/12/cropped-site-idendity-icon-1-32x32.png Danfoss http://saravanaelectronics.in 32 32 Danfoss – VLT 2800 Inverter Drives http://saravanaelectronics.in/product/danfoss-vlt-2800-inverter-drives/ http://saravanaelectronics.in/product/danfoss-vlt-2800-inverter-drives/#respond Tue, 26 Dec 2017 10:26:20 +0000 http://saravanaelectronics.in/?post_type=product&p=290 The Danfoss VLT® 2800 series are among the smallest multi-purpose drives in the market, designed for space saving side-by-side mounting. Choose to have it with Motor Coils, RFI filter, LC+1B filters.

Product Range

0.55 – 18.5 kW : (3 phase 380 – 480 V ± 10 %; 50/60 Hz)
0.37 – 1.5 kW : (Combined 1 and 3 phase 200 – 240 V ± 10 %; 50/60 Hz)
2.2 – 3.7 kW : (3 phase 200 – 240 V ± 10 %; 50/60 Hz)

Variable output frequency between 0 and 1000 Hz

]]>
http://saravanaelectronics.in/product/danfoss-vlt-2800-inverter-drives/feed/ 0
Danfoss – VLT® AQUA Drive FC 202 http://saravanaelectronics.in/product/vlt-aqua-drive-fc-202/ http://saravanaelectronics.in/product/vlt-aqua-drive-fc-202/#respond Tue, 26 Dec 2017 10:13:01 +0000 http://saravanaelectronics.in/?post_type=product&p=288 Maximum energy efficiency for water and wastewater applications]]>

Supply voltages and power range

1 x 200-240 V…1.1-22 kW
1 x 380-480 V…7.5-37 kW
3 x 200-240 V…0.25-45 kW
3 x 380-480 V…0.37 kW – 1 MW
3 x 525-600 V…0.75-90 kW
3 x 525-690 V…1.1 kW – 1.4 MW

Low harmonic drive

3 x 380-480 V…132-710 kW

12-pulse drive

3 x 380-500…250-1000 kW
3 x 525-690…250-1400 kW

Features and benefits

  • Assets are protected thanks to specially designed software that prevents, for example, water hammering
  • Energy efficiency is maximized as a result of the drives control algorithms and design which focus on reducing heat loss
  • High energy savings related to air conditioning are ensured due to the unique back-channel-cooling concept that transfers 90% of heat away from the room
  • Electromagnetic interference and harmonic distortion are reduced thanks to the built-in, scalable RFI filter and integrated DC link chokes
  • Perfect system integration and adaptation to the application are possible due to freely programmable warnings and alerts
  • 3–8% energy savings are achieved as a result of Automatic Energy Optimization

Applications

Centrifugal pumps and blowers, positive displacement blowers.
]]>
http://saravanaelectronics.in/product/vlt-aqua-drive-fc-202/feed/ 0
Danfoss – VLT® Midi Drive FC 280 http://saravanaelectronics.in/product/vlt-midi-drive-fc-280/ http://saravanaelectronics.in/product/vlt-midi-drive-fc-280/#respond Tue, 26 Dec 2017 08:01:19 +0000 http://saravanaelectronics.in/?post_type=product&p=286 Flexible, communicative and easy to use. Fits your application]]>

Supply voltages and power range

1 x 200-240 V…0.37-2.2 kW

3 x 200-240 V…0.37-3.7 kW

3 x 380-480 V…0.37-22 kW

Features and benefits

  • Compact design saves panel space
  • Easy and fast installation set-up due to flexible user interfaces
  • No need to install extra cooling equipment or oversize the drive as it is designed to operate at 45°C at full load and up to 55°C with derating
  • No need to install extra components thanks to integrated harmonic mitigation, RFI filters, brake choppers and functional safety (STO)
  • Integrated active Power Factor Correction (PFC) significantly reduces harmonic distortion and improves power supply quality
 

Applications

 Conveyors, mixers, packaging systems, pumps, fans and compressors.
]]>
http://saravanaelectronics.in/product/vlt-midi-drive-fc-280/feed/ 0
Danfoss – VLT® Refrigeration Drive FC 103 http://saravanaelectronics.in/product/vlt-refrigeration-drive-fc-103/ http://saravanaelectronics.in/product/vlt-refrigeration-drive-fc-103/#respond Tue, 26 Dec 2017 07:58:09 +0000 http://saravanaelectronics.in/?post_type=product&p=284 Save energy and extend the lifetime of refrigeration applications]]>

Supply voltages and power range

3 x 200-240 V…1.1-45 kW
3 x 380-480 V…1.1-710 kW
3 x 525-600 V…1.1-7.5 kW
3 x 525-690 V…75-630 kW

Features and benefits

  • Energy consumption and maintenance requirements are reduced thanks to a range of pump features such as the pump cascade controller and flow compensation
  • Optimum system efficiency is achieved by taking advantage of the drive’s software features
  • Challenging environments are no problem due to the drive’s coated electronics
  • The need for external cooling or oversizing is avoided as the drive operates efficiently in a maximum ambient temperature of 50°C without derating
  • There are no EMC concerns as a result of integrated DC link harmonic and EMC filters

Applications

Pumps, fans, compressors, condensers and evaporators.
]]>
http://saravanaelectronics.in/product/vlt-refrigeration-drive-fc-103/feed/ 0
Danfoss – Enhanced VLT® HVAC Drive FC 102 http://saravanaelectronics.in/product/enhanced-vlt-hvac-drive-fc-102/ http://saravanaelectronics.in/product/enhanced-vlt-hvac-drive-fc-102/#respond Tue, 26 Dec 2017 07:50:34 +0000 http://saravanaelectronics.in/?post_type=product&p=282 Get even more drive in your HVAC – with rock-bottom lifecycle costs in any climate]]>

Supply voltages and power range

3 x 200-240 V………………………….1.1-45 kW
3 x 380-480 V……………………..1.1-1000 kW
3 x 525-600 V…………………………1.1-90 kW
3 x 525-690 V………………………1.1-1400 kW

Low harmonic drive

3 x 380-480 V…132-710 kW

12-pulse drive

3 x 380-500 V…250-1000 kW
3 x 525-690 V…250-1400 kW

Features and benefits

  • Slim down your TCO. Ongoing demands for lower TCO are challenges the VLT® HVAC Drive can help you meet.
  • Install it outdoors in extreme climates. Searing heat and deep frost are all in a day’s work for the enhanced VLT® HVAC Drive. You get full reliability running this drive outdoors with temperature extremes from 50°C to minus 25°C.
  • Control multiple IE5 PM motors. Bring energy efficiency to a new level in your fan and pump applications. You can even control multiple IE5 permanent magnet (PM) motors using only a single drive.
  • Save time. You can parameterize and troubleshoot the drive from outside the AHU, thanks to the remote LCP. Maximize uptime by reducing the shutdown, since there is no need to open up the AHU and lock it down again afterwards.
  • Get the freedom to choose your favorite motor. Choose exactly the motor you prefer, for whatever reason from supply security to performance optimization. The enhanced VLT® HVAC Drive is not only optimized to control induction, permanent magnet and synchronous reluctance motor technologies; our development team is working all the time to include compatibility with upcoming motor technologies in future software updates as well.
  • Get the freedom to communicate. The ability to integrate the AC drive easily into your building automation system is a key to optimal control. The VLT® HVAC Drive features a number of HVAC-specific communication protocols, such as BACnet/IP, that give you flexibility of installation in both new and existing building automation systems.

Applications

Pumps, fans, compressors.
]]>
http://saravanaelectronics.in/product/enhanced-vlt-hvac-drive-fc-102/feed/ 0
Danfoss – VLT 5000 Inverter Drives IP20/IP54 http://saravanaelectronics.in/product/danfoss-vlt-5000-inverter-drives-ip20-ip54/ http://saravanaelectronics.in/product/danfoss-vlt-5000-inverter-drives-ip20-ip54/#respond Tue, 26 Dec 2017 07:42:42 +0000 http://saravanaelectronics.in/?post_type=product&p=280 The VLT 5000 has been superceded by the FC301 and FC302]]> Product range

  • 0.75 – 355 kW
  • (200 – 240 V, 380 – 500 V and 525 – 600 V)

Applications

  • The VLT® 5000 series suits all industrial applications.
  • The compact size saves valuable space.
  • The perfect speed matching to actual load reduces your energy costs.
]]>
http://saravanaelectronics.in/product/danfoss-vlt-5000-inverter-drives-ip20-ip54/feed/ 0
Danfoss – VLT® Micro Drive FC 51 http://saravanaelectronics.in/product/ninja-t-shirt/ http://saravanaelectronics.in/product/ninja-t-shirt/#respond Sun, 24 Dec 2017 09:14:51 +0000 http://saravanaelectronics.in/?post_type=product&p=34 Maximum strength with reduced installation costs  ]]>

Supply voltages and power range

1 x 200-240 V…0.18-2.2 kW
3 x 200-240 V…0.25-3.7 kW
3 x 380-480 V..0.37-22 kW

Features and benefits

  • Side-by-side mounting without derating is possible thanks to the compact, book-style design
  • Penetration of dust is minimized thanks to coated PCBs
  • Radio disturbance from motor cables is limited due to built-in RFI filters
  • Lifetime of the drive is extended and reliability improved as a result of the effective heat sink that removes heat from the electronics
  • Energy consumption can be reduced as kinetic energy in the application can be transformed into braking power to slow down the motor

Applications

Conveyors, pumps, fans, mixers, extruders, palletizers, packaging machines and other industrial appliances.
]]>
http://saravanaelectronics.in/product/ninja-t-shirt/feed/ 0
Danfoss – Enhanced VLT® AutomationDrive FC 301/FC 302 http://saravanaelectronics.in/product/logo-t-shirt/ http://saravanaelectronics.in/product/logo-t-shirt/#respond Sun, 24 Dec 2017 09:14:51 +0000 http://saravanaelectronics.in/?post_type=product&p=15 Versatile, reliable and consistently awesome]]>

Supply voltages and power range

3 x 200-240 V…0.25-37 kW
3 x 380-500 V…0.37 kW – 1.1 MW
3 x 525-600 V…0.75-75 kW
3 x 525-690 V…1.1 kW – 1.4 MW

Low harmonic drive

3 x 380-480 V…132-710 kW

12-pulse drive

3 x 380-500 V…250 kW – 1 MW
3 x 525-690 V…250 kW – 1.4 MW

Features and benefits

  • A wide operating temperature range of -25°C to +50°C without derating ensures reliable operation when your applications take your drive to the extremes
  • The flexible, modular design concept provides an extraordinarily versatile motor control solution
  • The new VLT® Wireless Communication Panel LCP 103 communicates wirelessly with MyDrive® Connect making it easier to perform commissioning, operation, monitoring and maintenance tasks
  • Back-channel cooling concept reduces costs, energy consumption and the size of the cooling system
  • New ‘ruggedized’ design reduces the potential negative effects of vibration
  • The need for PLC capacity is reduced thanks to Smart Logic Control
  • Low lifetime costs are ensured as the drive is highly resistant to wear and tear
  • The lifetime of electronics is prolonged due to back-channel cooling for enclosures D, E and F
  • Commissioning and upgrades are easy due to plug-in technology
  • High-precision position and synchronization thanks to availability of Integrated Motion Controller throughout the entire product range
  • Features such as intelligent heat management, Safe stop and Safe Torque Off ensure safe and energy-efficient operation of the drive
  • VLT® Motion Control Tool MCT 10 offers a customized commissioning experience

Applications

]]>
http://saravanaelectronics.in/product/logo-t-shirt/feed/ 0