+91 9363118587 +91 94431 18587 04563 224588

TP270 HMI – Display

Category: Tags: ,

Description

SIMATIC TP 270 10″ Touch panel 10.4″ STN color display 2 MB configuration memory.
Display
Design of display STN, 256 colors
Screen diagonal 10.4 in
Resolution (pixels)
● Horizontal image resolution 640 Pixel
● Vertical image resolution 480 Pixel
Backlighting
● MTBF backlighting (at 25 °C) 60 000 h
Control elements
Control elements Touch screen
Keyboard fonts
● Membrane keyboard No
— user-definable label membrane keys No
● Function keys No
— Number of function keys with LEDs 0
● System keys No
● Numeric keyboard Yes
● alphanumeric keyboard Yes
● hexadecimal keyboard Yes
● Multi-key operation No
Touch operation
● Design as touch screen Yes; analog, resistive
Connection type
● Type of connection for mouse/keyboard/barcode reader USB / USB / USB
Special operator controls
● Handwheel No
Installation type/mounting
Mounting position vertical
maximum permissible angle of inclination without external ventilation 35°
Supply voltage
UPS connectable (serial) Yes
Input current
Current consumption (rated value) 0.9 A
Power
Active power input, typ. 15 W
Processor
Processor type RISC 32-bit
Drives
Diskette drive No
CD-ROM No
Hard disk No
Memory
Type of memory Flash / RAM
Memory available for user data 2 048 kbyte
Battery
Backup battery
● Backup battery (optional) Yes; optional 3.6 V
● Backup time, min. 3 y
Type of output
Info LED No
Power LED No
Error LED No
Time of day
Clock
● Type Hardware clock, battery backup, synchronizable
● retentive Yes
● synchronizable Yes
Interfaces
Interfaces/bus type 2 x RS232, 1 x RS422, 1 x RS485 (max. 12 Mbit/s)
Number of RS 485 interfaces 1
● Transmission rate, max. 12 Mbit/s
USB port Yes; 1 x USB
PC card slot No
CF card slot 1 x CF card slot
Industrial Ethernet
● Industrial Ethernet interface No
Degree and class of protection
IP (at the front) IP65
IP (rear) IP20
Standards, approvals, certificates
Certifications CE, GL, ABS, DNV, LRS, FM Class I Div. 2, UL, cULus, EX Zone 2/22, C-TICK
Ambient conditions
Ambient temperature during storage/transportation
● min. -20 °C
● max. 60 °C
Relative humidity
● Operation, max. 85 %
Operating systems
pre-installed operating system Windows CE
Configuration
Configuration software
● Configuration tool ProTool Version 6 SP 3 or higher, or WinCC flexible Standard Version 2004 or higher (to be ordered separately)
Languages
Online languages
● Number of online/runtime languages 5
Project languages
● Languages per project 32
Functionality under WinCC (TIA Portal)
Libraries Yes
Number of Visual Basic Scripts
● Debugging in the simulator No
Task planner Yes
Help system Yes
● Number of characters per info text 70
● Number of tooltips 0
Message system
● Number of alarm classes 32
● Number of messages 4 000
● Bit messages Yes
— Number of bit messages 2 000
● Analog messages Yes
— Number of analog messages 2 000
● Telegram message procedure Alarm S Yes
● System messages HMI Yes
● System messages PLC No
● System messages, other (SIMATIC S7, Sinumerik, Simotion, etc.) No
● Lines 1
● Number of characters per message 70
● Number of process values per message 8
● Acknowledgment groups Yes
● Message indicator Yes
● acoustic feedback No
● First/last value Yes
Recipe management
● Number of recipes 300
● Data records per recipe 500
● Entries per data record 1 000
● Recipe memory 64 KB integrated Flash, expandable
Variables
● Number of variables per device 2 048
● Number of variables per screen 200
● Number of variables 2 048
● Type Date & Time 2 048
● Limit values Yes
● Multiplexing Yes
● Structures Yes
Images
● Number of configurable images 300
● Permanent window/default Yes
● Start screen configurable Yes
● Image selection by PLC Yes
● Image number in the PLC Yes
Image objects
● Text objects 10,000 text elements
● Number of I/O fields per image 200
● Number of date/time fields 30
● Index of screen context No
● Return Yes
● Graphics object Bit maps, icons, vector graphics
— Icons 1 000
— Icon (full screen) 0
Complex image objects
● Status/control With SIMATIC S7
● dynamic objects Diagrams, bar graphs, invisible buttons
— Number of objects per project 500
— Number of curve diagrams per image 5
● Methods Trend
● Bar graphs
— Number of bars per chart 10
● Sliders
— Number of slides per image 0
● Pointer instruments
— Number of analog indicators per image 0
● Limit value lines Yes
● Number of alphanumerical fields 1 000
— alphanumeric fields per image 100
● Number of numerical fields 1 000
— numerical fields per image 100
● Number of password fields 1 000
● Number of visible switches per project 1 000
— visible switches per image 100
— hidden switches per image 100
● Number of status switches per project 1 000
— Number of status switches per image 100
● Number of selector switches per project 1 000
— Selector switches per image 100
● Number of decade switches per project 0
— Decade switches per image 0
● Number of signal lamps per project 1 000
— Signal lamps per image 100
Attributes for dynamic objects
● Color change Yes
● X/Y movement Yes
● Hide Yes
● Angle of rotation No
Lists
● Number of text lists per project 500
● Number of entries per text list 256
● Number of graphics lists per project 400
● Number of graphic lists per image 10
● Number of entries per graphics list 255
Archiving
● Number of archives per device 20
● Number of measuring points per project 20
● Number of entries per archive 10 000
● Message archive Yes
● Process value archive Yes
● Archiving methods Sequence archive, circular log, alarm log, process value archive
— Sequential archive Yes
— Short-term archive Yes
● Memory location CF card, Ethernet
— PC card No
— CF card Yes
— USB memory No
— Ethernet Yes
● Data storage format CSV file, readable, e.g. with MS Excel, MS Access
— CSV Yes
— TXT No
● external evaluation Readable, e.g. with MS Excel, MS Access, etc.
● Size of archive depending on free memory on ext. card/stick or on free hard disk space via network drive
● Online evaluation via trends
— using trend curves Yes
Filters
● cyclic Yes
● Tolerance Yes
● Change Yes
Security
● Number of user groups 50
● Number of user rights 32
● Password export/import Yes
Logging through printer
● Recording/Printing Alarms, report (shift report), color print, hardcopy
Transfer (upload/download)
● Transfer of configuration MPI/PROFIBUS DP, serial, USB, Ethernet, automatic transfer recognition
Process coupling
● Connection to controller S5, S7-200, S7- 300/400, TI 505, Win AC, PC (TCP/IP), SINUMERIK, SIMOTION, Allen Bradley (DF1), Allen Bradley (DF485), Mitsubishi (FX), Telemecanique (ADJUST), OMRON (LINK/Multilink), Modicon (Modbus), for further non-Siemens drivers, see section on “System interfaces”
● S7-200 Yes
— PPI (point-to-point) Yes
— PPI network No
— MPI Yes
— PROFIBUS DP Yes
● S7-300/400 Yes
— MPI Yes
— PROFIBUS DP Yes
— PROFINET No
● S5 Yes
— serial Yes
— PROFIBUS DP Yes
● TI 505 Yes
● Allen Bradley (DF1) Yes
● Allen Bradley (DF485) Yes
● Mitsubishi (FX) Yes
● Mitsubishi (MP4) Yes
● Telemecanique (ADJUST) Yes
● Telemecanique (Uni-Telway) Yes
● OMRON (LINK/Multilink) Yes
● Modicon (Modbus) Yes
● GE-Fanuc (SNP) Yes
Functions
● Key repeat No
● TAB sequence Yes
● Calculating functions Yes
● Animate Yes
● Menu tree editor No
● Unit switchover No